Metisafe® Class III Biological Safety Cabinets works under principles with %100 HEPA filtered fresh air to work chamber without recirculation. Exhausting through HEPA filters also protects the environment. Airflow principles of Class III Cabinets which can also be applicable with carbon filter provides safe work with the biological risk level of 3/4 agents and also with cytotoxic gas & materials. Pre/HEPA-filtered air supplied through the top of the cabinet and pass-box provides the work zones with protection under ISO-5 class laminar airflow. Total air in the work chamber is fully exhausted without recirculation through exhaust blower fan to the atmosphere by keeping the working area under negative air pressure. In addition to the primary air barrier accomplished by the negative pressure within the working zone, the design of double-wall negative plenum offered by Metisafe cabinet prevents particle from escaping to surroundings and zero leakage is ensured.
Main Body & Design |
|
Pass-Box |
|
Microprocessor Control Unit & Display |
|
Audio-Visual Alarm Parameters |
|
Quality and Certificates |
|
Internal Dimensions (WxLxH) mm | 1250x610x675 | |
External Dimensions (WxLxH) mm | 1370x843x1678 | |
Pass-Box Dimensions (WxLxH) mm | 454x566x410 | |
Support Stand (WxLxH) mm | 1370x843x744 | |
Support Stand Height From Ground | 840 mm | |
Negative pressure (Pa) | 250 < | |
Exhaust Air velocity (m3/s) | 450 < | |
Downflow Hava Hızı (m/s) | 0.38 m/s ± %5 | |
HEPA Filter Types (EN 1822) | Main Filter | H14 HEPA, 0,3 µm %99.995 < filtration efficiency |
Exhaust Filter | H14 HEPA, 0,3 µm %99.995 < filtration efficiency | |
Pre-Filter | EU4 | |
Clean Area Class | EN14644 | < ISO 5 |
FED209E | < Class 100 | |
Exhaust Fan Motor Capacity | Up to 10 m horizontal & 3 m vertical duct length | |
Working Table | Standard | 304 Stainless Steel |
Optional | 316L Stainless Steel | |
Noise Level | Normal Mode | < 56 dB(A) |
Standby Mode | < 50 dB(A) | |
Front Glass | < 6 mm Lamine | |
Front Glass Gloves Entry Numbers | 2 | |
Working Area Illumination (Lux) | 850 – 1250 Lux | |
Power consumption (kW) | Fan Filter Unit | 200 W |
Illumination | 50 W | |
UV Lamp | 30 W | |
Electrical socket voltage and current | 220-240 VAC / 16A | |
Supply Voltage/Frequency/Power/Current | 220-240 VAC / 16A | |
Pack/Palette Dimensions (WxLxH) mm | 1645x980x1840 | |
Weight (kg), with Pass-Box | 280 |
Internal Dimensions (WxLxH) mm | 1554x610x675 | |
External Dimensions (WxLxH) mm | 1674x843x1678 | |
Pass-Box Dimensions (WxLxH) mm | 454x567x410 | |
Support Stand (WxLxH) mm | 1674x843x744 | |
Support Stand Height From Ground | 840 mm | |
Negative pressure (Pa) | 250 < | |
Exhaust Air velocity (m3/s) | 450 < | |
Downflow Hava Hızı (m/s) | 0.38 m/s ± %5 | |
HEPA Filter Types (EN 1822) | Main Filter | H14 HEPA, 0,3 µm %99.995 < filtration efficiency |
Exhaust Filter | H14 HEPA, 0,3 µm %99.995 < filtration efficiency | |
Pre-Filter | EU4 | |
Clean Area Class | EN14644 | < ISO 5 |
FED209E | < Class 100 | |
Exhaust Fan Motor Capacity | Up to 10 m horizontal & 3 m vertical duct length | |
Working Table | Standard | 304 Stainless Steel |
Optional | 316L Stainless Steel | |
Noise Level | Normal Mode | < 58 dB(A) |
Standby Mode | < 50 dB(A) | |
Front Glass | < 6 mm Lamine | |
Front Glass Gloves Entry Numbers | 2 | |
Working Area Illumination (Lux) | 850 – 1250 Lux | |
Power consumption (kW) | Fan Filter Unit | 170 W |
Illumination | 50 W | |
UV Lamp | 30 W | |
Electrical socket voltage and current | 220-240 VAC / 16A | |
Supply Voltage/Frequency/Power/Current | 220-240 VAC / 16A | |
Pack/Palette Dimensions (WxLxH) mm | 1875x875x1840 | |
Weight (kg), with Pass-Box | 330 |