Class I biological safety cabinets are primary barriers for the investigation of non-volatile materials or samples with unknown biological risk. After the entrance of indoor air through front window aperture of the cabinet, the air sweeps the work cabinet and surfaces in a non-turbulent way. The internal air is exhausted from the cabinet after passing through HEPA filter and protects the indoor environment from potentially dangerous particles. Since the Class I BSC does not protect sample/material, further, aseptic or sterile analysis of working material is not suitable.
Main Body & Design Parameters |
|
Microprocessor Control Unit & Display Parameters |
|
Audio-Visual Alarm Parameters |
|
Quality and Certificates |
|
Optional |
|
Internal Dimentions (WxLxH) mm | 875x680x720 | |
External Dimentions (WxLxH) mm | 995x833x1372 | |
Support Stand (WxLxH) mm | 995x793x785 | |
Support Stand Height From Ground | 855 mm | |
Inflow Air Flow Velocity (m/s) | 0.50 m/sn ± %5 | |
Filters (EN 1822) | Pre / Exhaust Filter | F5 / Optional |
Main Filter | H14 HEPA, 0,3 µm particule %99.995 < filtration efficiency | |
Working Table | Standart | 304 Stainless Steel |
Optional | 316L Stainless Steel | |
Front Glass | < 6 mm Lamine | |
Front Glass Aperture - Fixed (cm) | 46,5 cm | |
Motorized Front Glass (optional) | Standart-Preset | 200cm ± 10mm |
Maximum Height | 530cm ± 10mm | |
Noise Level | Normal Mod | < 58 dB(A) |
Standby Mode | < 50 dB(A) | |
Working Area Illumination (Lux) | 850 – 1250 Lux | |
Power consumption (kW) | Fan Filter Unit | 105 W |
Illumination | 50 W | |
UV Lamp | 30 W | |
Electrical socket voltage and current | 220-240 VAC / 16A | |
Supply Voltage / Frequency /Power / Current | 230 VAC / 50 Hz / 2500 W / 16A | |
Pack/Palette Dimensions (WxLxH) mm | 1270x970x1770 | |
Weight (kg), without support stand | 160 kg |
Internal Dimentions (WxLxH) mm | 1180x680x720 | |
External Dimentions (WxLxH) mm | 1300x833x1372 | |
Support Stand (WxLxH) mm | 1300x793x785 | |
Support Stand Height From Ground | 855 mm | |
Inflow Air Flow Velocity (m/s) | 0.50 m/sn ± %5 | |
Filters (EN 1822) | Pre / Exhaust Filter | F5 / Optional |
Main Filter | H14 HEPA, 0,3 µm particule %99.995 < filtration efficiency | |
Working Table | Standart | 304 Stainless Steel |
Optional | 316L Stainless Steel | |
Front Glass | < 6 mm Lamine | |
Front Glass Aperture - Fixed (cm) | 46,5 cm | |
Motorized Front Glass (optional) | Standart-Preset | 200cm ± 10mm |
Maximum Height | 530cm ± 10mm | |
Noise Level | Normal Mod | < 58 dB(A) |
Standby Mode | < 50 dB(A) | |
Working Area Illumination (Lux) | 850 – 1250 Lux | |
Power consumption (kW) | Fan Filter Unit | 200 W |
Illumination | 50 W | |
UV Lamp | 30 W | |
Electrical socket voltage and current | 220-240 VAC / 16A | |
Supply Voltage / Frequency /Power / Current | 230 VAC / 50 Hz / 2500 W / 16A | |
Pack/Palette Dimensions (WxLxH) mm | 1575x970x1770 | |
Weight (kg), without support stand | 190 kg |
Internal Dimentions (WxLxH) mm | 1485x680x720 | |
External Dimentions (WxLxH) mm | 1605x833x1372 | |
Support Stand (WxLxH) mm | 1605x793x785 | |
Support Stand Height From Ground | 855 mm | |
Inflow Air Flow Velocity (m/s) | 0.50 m/sn ± %5 | |
Filters (EN 1822) | Pre / Exhaust Filter | F5 / Optional |
Main Filter | H14 HEPA, 0,3 µm particule %99.995 < filtration efficiency | |
Working Table | Standart | 304 Stainless Steel |
Optional | 316L Stainless Steel | |
Front Glass | < 6 mm Lamine | |
Front Glass Aperture - Fixed (cm) | 46,5 cm | |
Motorized Front Glass (optional) | Standart-Preset | 200cm ± 10mm |
Maximum Height | 530cm ± 10mm | |
Noise Level | Normal Mod | < 58 dB(A) |
Standby Mode | < 50 dB(A) | |
Working Area Illumination (Lux) | 850 – 1250 Lux | |
Power consumption (kW) | Fan Filter Unit | 170 W |
Illumination | 50 W | |
UV Lamp | 30 W | |
Electrical socket voltage and current | 220-240 VAC / 16A | |
Supply Voltage / Frequency /Power / Current | 230 VAC / 50 Hz / 2500 W / 16A | |
Ambalaj Boyutları (ExDxY) mm | 1880x970x1770 | |
Weight (kg), without support stand | 220 kg |
Internal Dimentions (WxLxH) mm | 1790x680x720 | |
External Dimentions (WxLxH) mm | 1910x833x1372 | |
Support Stand (WxLxH) mm | 1910x793x785 | |
Support Stand Height From Ground | 855 mm | |
Inflow Air Flow Velocity (m/s) | 0.50 m/sn ± %5 | |
Filters (EN 1822) | Pre / Exhaust Filter | F5 / Optional |
Main Filter | H14 HEPA, 0,3 µm particule %99.995 < filtration efficiency | |
Working Table | Standart | 304 Stainless Steel |
Optional | 316L Stainless Steel | |
Front Glass | < 6 mm Lamine | |
Front Glass Aperture - Fixed (cm) | 46,5 cm | |
Motorized Front Glass (optional) | Standart-Preset | 200cm ± 10mm |
Maximum Height | 530cm ± 10mm | |
Noise Level | Normal Mod | < 62 dB(A) |
Standby Mode | < 50 dB(A) | |
Working Area Illumination (Lux) | 850 – 1250 Lux | |
Power consumption (kW) | Fan Filter Unit | 200 W |
Illumination | 50 W | |
UV Lamp | 30 W | |
Electrical socket voltage and current | 220-240 VAC / 16A | |
Supply Voltage / Frequency /Power / Current | 230 VAC / 50 Hz / 2500 W / 16A | |
Ambalaj Boyutları (ExDxY) mm | 2185x970x1770 | |
Weight (kg), without support stand | 280 kg |